Comparison of Short-Term Clinical Outcomes of Hook Plate and Continuous Loop Double Endobutton Fixations in Acute Acromioclavicular Joint Dislocation

Afshar, A.R and Shariyate, M.J and Taleb, H and Tabrizi, A (2019) Comparison of Short-Term Clinical Outcomes of Hook Plate and Continuous Loop Double Endobutton Fixations in Acute Acromioclavicular Joint Dislocation. Archives of bone and joint surgery, 7 (6). pp. 545-550.

[img]
Preview
Text
1622.pdf

Download (740kB) | Preview

Abstract

This study was conducted to evaluate the clinical outcomes of the acromioclavicular joint (ACJ) fixation with hook plate (HP) and continuous loop double endobutton fixation (CLDE) in the treatment of acute ACJ dislocation. Methods: This retrospective study was conducted on eight patients with HP and nine patients with CLDE fixations for acute ACJ dislocations. The subjects were evaluated by various criteria, including disabilities of the Arm, Shoulder, and Hand (DASH), American Shoulder and Elbow Surgeons Standardized Shoulder Assessment (ASES), University of California, Los Angeles (UCLA) shoulder rating scale, Shoulder Constant score, Simple Shoulder Test (SST), and coracoclavicular (CC) distance. Results: The differences between the mean scores of the visual analog scale for pain, DASH, ASES, UCLA shoulder rating scale, and Shoulder Constant, and SST were statistically significant in favor of the CLDE group. Mean difference of CC distance was 8.6±0.9 mm in the HP group; however, it was 11.6±1.2 mm in the CLDE group. The operation time was shorter in the HP fixation, compared to that in the CLDE fixation (51±13.3 versus 105±9.7 min; P<0.001 and P=0.008). There were six concomitant subacromial erosions and osteoarthritis in the ACJ of the HP group. Conclusion: The CLDE fixation was reported with better clinical outcomes than HP fixation; however, it was a technically demanding procedure. The HP maintained the CC distance better than CLDE with a technically easy application. The HP requires a second surgery for the removal and development of subacromial erosion and osteoarthritis of the ACJ that can be regarded as major concerns

Item Type: Article
Uncontrolled Keywords: Acromioclavicular dislocation, Closed-loop, Double endobutton, Hook plate
Subjects: R Medicine > R Medicine (General)
Depositing User: Unnamed user with email gholipour.s@umsu.ac.ir
Date Deposited: 07 Jan 2020 07:38
Last Modified: 07 Jan 2020 07:38
URI: http://eprints.umsu.ac.ir/id/eprint/5727

Actions (login required)

View Item View Item